Amplitude range |
6×(0~30A)/phase;accuracy:0.5% |
|
Six-phase current parallel output maximum |
180A |
|
Phase current long-term allowable working value |
10A |
|
power |
300VA/phase |
|
Six-phase parallel maximum power |
900VA |
|
Allowable working time at maximum output of six-phase parallel |
10s |
|
Frequency Range |
0~1000Hz;accuracy:0.001Hz |
|
Harmonic order |
2~20次;phase:0~360°;accuracy:0.1° |
|
DC current source |
|
|
Amplitude |
20A/phase |
|
power |
300VA/phase |
|
Accuracy |
0.50% |
|
AC voltage source |
|
|
Amplitude range |
6×(0~125V);accuracy:0.5% |
|
Line voltage range |
0~250V |
|
Phase voltage / line voltage output power |
70VA/100VA |
|
Frequency Range |
0~1000Hz;accuracy:0.001Hz |
|
Harmonic order |
2~20次;phase:0~360°;accuracy:0.1° |
|
DC voltage source |
|
|
Phase voltage output amplitude |
0~±150V |
|
Accuracy |
0.50% |
|
Line voltage output amplitude |
0~±300V |
|
Phase voltage / line voltage output power |
90VA/180VA |
|
Switching terminal |
|
|
Digital input terminal |
8对 |
|
Empty contact |
1~20mA,24V Active inside the device |
|
Potential flip |
0~6VDC as low level;15~250VDC as high level |
|
Switch output terminal |
4 pairs, empty contacts, breaking capacity: 110V / 2A, 220V / 1A |
|
Time measurement range |
|
|
range |
1ms~9999s |
|
measurement accuracy |
1ms |
|
volume and weight |
|
|
volume |
455×530×220mm3 |
|
weight |
about 30kg |
|
power supply |
|
|
AC |
220V±10% ; 50Hz,15A |